Ask A Question II

Ask 10 questions in a forum.

View Article



Insight On Demand Tuning, Error, Level Control

Hello, I need to tune a level control loop output from oscillating to big. The level is used to control level in a column and simple feedback loop, normally in AUTO.The problem is the pv tracks the sp...

View Article

How To Read Data DeltaV to PLC?

Hello, Currently our DeltaV is setup to read data serially from a PLC. How do I setup a module in DeltaV so that the PLC can read a AI or DO value from DeltaV? Thank ou

View Article

Unable to connect to live device in AMS Device Manager

Hello, We have over 3000 Hart devices and I can not connect to any of the devices AMS Device Manager.This is the error message I get on all HART devices in AMS:http://i.imgur.com/Y4UbVtL.pngMay I...

View Article

Image may be NSFW.
Clik here to view.

Not Communicating With Device, HART Diagnostics

Hello, I have a valve setup in the field on Analog Output Hart Card. I am getting intermittently ( approx every 15 minutes Not Communicating With Device) warning alarms, but the valve is still working...

View Article


Discussion Starter I

Start a discussion in a forum that receives 5 replies.

View Article

Rank: Grand Master

Have between 500 and 999999 points.

View Article

DI Card Input Signal Loss?

Hello, We have an on/ff valve that occasionally loses the input 120V signal and Operations see  "Confirmation Closed Lost" lost. The valve is energized to close, so we have a PV - SP mismatched is what...

View Article


How to Setup ModBus Connection for DCS

Hello, I would like to setup a DeltaV standalone computer at a PLC vendor location to test our DCS graphics and modbus connection. We currently have DeltaV version 11.3 at the plantwide site. We have...

View Article


Regulators

Learn best practices, ask technical questions & join pressure regulator discussions. Over 16,000 process automation engineers use Emerson Exchange 365.

View Article

Nitrogen Pressure Regulator Not Maintaining Pressure

Hello, My plant uses nitrogen for plant air incase our air compressor trips off and loses normal plant air.Normally the nitrogen air is regulated with a regulator at 200 psi on upstream and 100 psi...

View Article

Image may be NSFW.
Clik here to view.

Unable to Control Level PID output

Hello, I have a level controller PID and its doing this:Why when I set the PID Parameter STRUCTURE to PID Action on Error or PI Action on Error, D Action on PV  , and MODE to auto, the output does not...

View Article

Tuning a Level with Valve Open and Close Timing

Hello.I started a new thread to for opinions or recommendations for the following Level Application:Existing SetupThe design is currently setup like:Level Controller maintain levels of dry pellets with...

View Article


Discussion Starter II

Start 25 discussions in a forum that each receives 5 replies.

View Article

Tuning a Flow Loop with Unstable PV

Hello, Today I attempt to tune a flow loop that is normally set in AUTO. When I place the loop in MAN to stabilize the flow before step change, I notice the PV (actually flow) was still oscillating and...

View Article


Moving Modules To Another Area

Hello, I have task to move about 200 modules (in different areas) to a new existing areas. We are doing some alarm management and need to makes sure the right alarm activates for the right area. All...

View Article

PID Open 100% on bad PV

Hi all, I am needing a little help with a PID, when I get a bad Pv from my input my control valve is failing closed is there a way I can get it to fail open?

View Article


Image may be NSFW.
Clik here to view.

Automatically Stopping Motor with Fail Active is True

Hello, I use DC block to start and stop motor and monitor running status. Sometimes, while motor is running (set point equal START, and PV is equal to RUNNING), something electrical happens and the...

View Article

Insight On Demand Tuning, Error, Level Control

Hello, I need to tune a level control loop output from oscillating to big. The level is used to control level in a column and simple feedback loop, normally in AUTO.The problem is the pv tracks the sp...

View Article

How to Setup ModBus Connection for DCS

Hello, I would like to setup a DeltaV standalone computer at a PLC vendor location to test our DCS graphics and modbus connection. We currently have DeltaV version 11.3 at the plantwide site. We have...

View Article